The HELIOS-35 source is designed for X-ray applications with anode voltage adjustment range up to a maximum of 70kV. The device is characterized by its small size, high conversion efficiency and an analogue digital interface with RS-232 and Ethernet that simplify the integration.
The sophisticated inverter-type control circuit provides excellent anode voltage regulation with low crest noise to the X-ray tube. The inverter regulates the filament power, thus achieving a high stability of the regulating power which contributes to the anodic current stability and to the X-ray flux intensity.
The microcontroller placed on the electronic board performs control functions with second level feedbacks, linearizing the reading and writing functions. It also controls the temperature and the compliance of the operating conditions limits; in case of an exception, it generates appropriate alarm signals.
The generator implements an event recording mechanism in order to facilitate the diagnostic process of any potential failure.
Typical applications
X-ray scanning
Food inspections
Non-destructive testing
OEM customization
Typical applications
X-ray scanning
Food inspections
Non-destructive testing
OEM customization
Power Supply
Supply voltage 220÷240Vac 10% 50/60Hz
Current 1Arms max a 110Vac
Power supply frequency 50/60 Hz
Input power 220Watt max
Protection fuse 1 A T Vac 220V
Conductor cable section 1 mm2
Mechanics
Dimensions 175 x 230 x 150 mm
Weight 12kg